Up to 4 stops 25 I/O - terminals 4 configurable keys Designed for VVVF lifts Led indication for inputs and outputs Power supply = 24V Consumption ~ 200mA 2 speeds May be used with an extender for decoding of BCD or 7-segment code
LCC-4 T (Goods)
Up to 4 stops; 25 I/O - terminals; 4 configurable keys May be used with an extender for decoding of BCD or 7-segment code It can be used either with hydraulic or VVVF lifts Led indication of inputs and outputs Power supply = 24V Consumption ~ 200mA
LCC-4 L (Platform)
Automobile platform Up to 4 stops (when an extender is used) Up to 3 stops by default 1 speed An automatic door at each floor Power supply = 24V Consumption ~ 200mA
LCC-4 P (Goods with Automatic doors)
Up to 4 stops With automatic doors It can be used either with hydraulic or VVVF lifts Led indication for inputs and outputs 2 speed Door reversing Power supply = 24V Consumption ~ 200mA
LCC-16
Up to 16 stops; It can be used either with hydraulic or VVVF lifts; Due to 8 configurable keys the parameters can be adjusted to the specific needs of the customer (Number of stops; Opened/closed door; Stay on floor time and others) Power supply = 24V Consumption ~ 200mA
LCC-16 Programmer
A programmer for setting and changing the parameters of the controllers